The AH Series
AH27 / AH24 / AH21 SPECIFICATIONS
- Dimensions: 16” x 17” x 3.25”
- Shipping Weight: 16 lbs.
- Cover: Aluminum / Powder Coated
- Body/Heat Exchanger: Copper
- Element: 3 Brass Flange/Copper
- Pipe fittings: 3/4" NPT
- Activation flow rate: .25 gallon
- Operation Pressure: Min 25 PSI, Max 150
AH18 / AH16 / AH14 SPECIFICATIONS
- Dimensions: 16” x 13.5” x 3.25”
- Shipping Weight: 12 lbs.
- Cover: Aluminum / Powder Coated
- Body/Heat Exchanger: Copper
- Element: 3 Brass Flange/Copper
- Pipe fittings: 3/4" NPT
- Activation flow rate: .25 gallon
- Operation Pressure: Min 25 PSI, Max 150
Electrical Specifications:
| Model | KW @ 240V | Req.Breaker | Voltage | Max Power | Wire Gauge |
|---|---|---|---|---|---|
| AH-27 | 27 | 125 AMP | 208/220/240 | 112.5 AMPS | # 2/2 |
| AH-24 | 24 | 100 AMP | 208/220/240 | 100 AMPS | # 2/2 |
| AH-21 | 21 | 100 AMP | 208/220/240 | 87.5 AMPS | # 2/2 |
| AH-18 | 18 | 80 AMP | 208/220/240 | 75 AMPS | # 4/2 |
| AH-16 | 16 | 70 AMP | 208/220/240 | 66 AMPS | # 4/2 |
TEMPERATURE RISE CHART
The chart below illustrates the maximum flow rate and temperature rise that can be achieved for the different AH Models. Most people shower at a temperature of between 98F and 104F. The chart is based on a 240 volt input voltage and maximum flow rates are listed for various incoming water temperature levels. If your home or business has less than 240 volt power (208v), your maximum flow rate will be lower. Simply look up your incoming water temperature and desired flow rate to determine your model choice. Don't forget that incoming water temperature may change throughout the year depending on the season.
MODEL SELECTOR